BISTRO LINE
Gas-Fired Stone Hearth Oven
Commercial Dual Burner, Pita Oven Models
BISTRO 4836 (PITA OVEN)
WS-BL-4836-RFG-LR-(NG, LP)
BISTRO 4343 (PITA OVEN)
WS-BL-4343-RFG-LR-(NG, LP)
BISTRO 4355 (PITA OVEN)
WS-BL-4355-RFG-LR-(NG, LP)
CUSTOM MODELS (PITA OVEN)
CS-REC-8-RFG-LR-(NG, LP)
CS-REC-9-RFG-LR-(NG, LP)
CS-REC-11-RFG-LR-(NG, LP)
Installation and
Operation Manual
woodstone-corp.com
Revised April 2015
Doc no: M0028.02
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
tf. 800.988.8103
t. 360.650.1111
f. 360.650.1166
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Operation Manual

BISTRO LINEGas-Fired Stone Hearth OvenCommercial Dual Burner, Pita Oven ModelsBISTRO 4836 (PITA OVEN)WS-BL-4836-RFG-LR-(NG, LP) BISTRO 4343 (PITA OV

Seite 2 - TABLE OF CONTENTS

10CLEARANCES1. The Wood Stone Bistro oven should have a minimum 1-inch clearance to combustibles from all sides, 6-inch clearance to combustibles fro

Seite 3 - DUAL BURNER OVEN

11Flue collarWOOD STONE OVENS SHOULD BE VENTED IN ACCORDANCE WITH NFPA 96 AND/OR ALL PERTINENT NATIONAL, REGIONAL AND LOCAL CODES CONCERNING SUCH APPL

Seite 4 - CAUTIONS AND WARNINGS

12An ongoing program of product improvement may require us to changespecifications without notice. WS-BL-RFG-LR, Revised April 2015.Doc no: M0028.02inf

Seite 5

13DISASSEMBLYBistro Dual Burner Oven Installation and Operation Manual2. To begin disassembly of the Mantle, remove the 4 screws from the Mantle Face

Seite 6 - 1,800 lbs

14DISASSEMBLYBistro Dual Burner Oven Installation and Operation Manual5. Using the upper forklift pockets, support the oven with a forklift or other

Seite 7 - 2,100 lbs

15LIFTING THE OVENBistro Dual Burner Oven Installation and Operation Manual1. Use a forklift or other suitable lifting means to set the oven body ont

Seite 8 - 2,500 lbs

166. Attach strap to the clevises at the top of each Pickeye Insert. Using an appropriate hoist or lift, tilt the oven on its back, onto 4x4" bl

Seite 9 - MOVING THE OVEN

17An ongoing program of product improvement may require us to changespecifications without notice. WS-BL-RFG-LR, Revised April 2015.Doc no: M0028.02inf

Seite 10 - INSTALLATION CLEARANCES

18ASSEMBLYBistro Dual Burner Oven Installation and Operation ManualFollow these instructions only if the oven was shipped disassembled, or disassemble

Seite 11 - OVEN VENTING

19ASSEMBLYBistro Dual Burner Oven Installation and Operation ManualMake sure the pallet jack wheels do not contact the underside of the fork pocket wh

Seite 12 - HOOD SPECIFICATIONS

2An ongoing program of product improvement may require us to changespecifications without notice. WS-BL-RFG-LR, Revised April 2015.Doc no: M0028.02info

Seite 13 - Cover Screws

20ASSEMBLYBistro Dual Burner Oven Installation and Operation Manual7. Install the Mantle. Fasten using 3 bolts / washers and 2 carriage bolts (see il

Seite 14 - DISASSEMBLY

2111. Make gas connection at the rear of the Control Box. Gas and electrical connections must comply with all relevant national and local codes, and i

Seite 15 - LIFTING THE OVEN

22The installation must conform with local codes, or in the absence of local codes with the National Fuel Gas Code, ANSI 223.1 or Natural Gas Installa

Seite 16

23An ongoing program of product improvement may require us to changespecifications without notice. WS-BL-RFG-LR, Revised April 2015.Doc no: M0028.02inf

Seite 17 - EXPLODED PARTS DIAGRAM

24Flame Height Control Knob (left)Use these knobs to raise/lower the flame to control the oven temperature. Dual burner models have (2) knobs which are

Seite 18 - ASSEMBLY

25INITIAL OVEN START-UP FOR DUAL BURNER BISTRO MODELS FIRST DAY1. Make sure main gas supply is on (valve parallel with gas line).2. Push I/O button

Seite 19

26GENERAL DAILY OVEN OPERATIONThe oven floor temperature is displayed on the controller readout.END OF THE DAYPush I/O button on the controller. All ga

Seite 20

27OVEN INTERIORWood Stone recommends the use of long-handled brushes for sweeping up surface debris that will accumulate on the floor of the oven durin

Seite 21

28Please contact Wood Stone at 1-800-988-8103 should service be necessary, or if you have any questions about your oven. Our service hours are 8am to

Seite 22 - UTILITY CONNECTIONS

29DUAL BURNER BISTRO - ALL MODELS120 VAC ELECTRICAL DIAGRAMDual RFGDATE:DIAG #:WD075 Rev. 111/12/2014Bellingham, WA +1(360)650-1111 www.woodstone-co

Seite 23 - General Arrangement

3INSTALLATION AND OPERATION MANUAL FORTHE WOOD STONE DUAL BURNER BISTRONATURAL GAS OR PROPANE FUELED DUAL BURNER STONE HEARTH OVENWS-BL-4836-RFG-LR-(N

Seite 24 - CONTROLLER

30DUAL BURNER BISTRO - ALL MODELS240 VAC ELECTRICAL DIAGRAMDual RFGDATE:DIAG #:WD078 Rev. 07/17/2014Bellingham, WA +1(360)650-1111 www.woodstone-cor

Seite 25 - INITIAL START-UP

31120 VAC Oven Circuit120 VAC to OvenS1 is a Double Pole, Single Throw (DPST) switch provided by others.120 VAC to FanWired by othersS1120 VAC Fan Cir

Seite 26 - OVEN OPERATION

32ALL WARRANTY SERVICE MUST BE PRE-APPROVED BY WOOD STONEWood Stone warrants its equipment to the original purchaser against defects in material or ma

Seite 27 - DAILY MAINTENANCE

4WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.IMPORTANT: Consult

Seite 28 - TROUBLESHOOTING GUIDE

5SAVE THE INSTRUCTIONSFOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance

Seite 29 - 120 VAC ELECTRICAL DIAGRAM

6UTILITIES SPECIFICATIONSGas: 3/4 inch FNPT gas inlet 105,000 BTU/hr Natural Gas (NG) OR100,000 BTU/hr Propane (LP) Maximum gas inlet pressure1/2 psi

Seite 30 - 240 VAC ELECTRICAL DIAGRAM

7UTILITIES SPECIFICATIONSGas: 3/4 inch FNPT gas inlet 105,000 BTU/hr Natural Gas (NG) OR100,000 BTU/hr Propane (LP) Maximum gas inlet pressure1/2 psi

Seite 31 - INTERLOCK DIAGRAM

8Side viewRear viewPlan viewREV:LEGEND:PART #:WS-BL-4355 shownBL-RFG-LR (Pita Oven) - All SizesGeneral Arrangement5/30/2013bena1DWN BY:SHEET:Bellingha

Seite 32 - LIMITED WARRANTY

9The oven can be moved over a flat surface with a pallet jack using the LOWER forklift pockets. If the oven is to be installed against a wall, you may